Abstract

Low-temperature sterilization methods are widely used nowadays for the sterilization of thermosensitive materials. This literature review aims to identify the antimicrobial activity, toxicity, adverse events and uses of low-temperature sterilization methods, The Medline and Google scholar databases were used to find articles published between 2006 and October 2009. Keywords in English and the and operator were used for subject specification, A total of fifteen articles were found, with the following results: (1) plasma sterilization process showed positive results compared with ethylene oxide sterilization process; (2) the reprocessing (sterilizing for the second, third, or more times) of laboratory
catheters destroys its properties; (3) nowadays, there are no laws regulating the reprocessing of disposable materials and its safety is questionable; (4) the
sterilization of bone surfaces with ethylene oxide is not effective.

Downloads

Download data is not yet available.

Author Biographies

Eveline Lucena Vasconcelos, Universidad de Granada

1 Universidad de Granada, Facultad de Medicina, Departamento de Salud Pública. Av. De Madrid, 11, 18012, Granada, España.
Correspondencia con el actor/Correspondence to: EL VASCONCELOS. E-mail: <evelinelucena@gmail.com>.

José Francisco Guillen Solvas, Universidad de Granada

Universidad de Granada, Facultad de Medicina, Departamento de Salud Pública. Av. De Madrid, 11, 18012, Granada, España.

References

Associação Paulista de Estudos e Controle de Infecção Hospitalar. Esterilização de artigos em unidades de saúde. São Paulo: APECIH; 2003.

Brasil. Ministério da Saúde. Resolução RDC nº 50, de 21 fevereiro de 2002. Dispõe de regulamento técnico para planejamento, programação, elaboração e avaliação de projetos físicos de estabelecimentos de saúde. Diário oficial da União. 2002 21 fev; Seção 1.

Rutala WA, Weber DJ. Low temperature sterilization tecnologies: do we need redefine “sterilization”? Infect Control Hosp Epidemiol. 1996; 17(2):87-91.

Rutala WA, Gergen MF, Weber DJ. Comparative evaluation of the sporicidal activity of new lowtemperature sterilization technologies: ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid. Am J Infect Control. 1998; 26(4): 393-8.

Vasconcelos EL. Comparación del coste de los diversos métodos de esterilización para material termosensible utilizados en la Central de Esterilización del Hospital Universitario San Cecilio de Granada [tesis]. Granada: Universidad de Granada; 2011.

Alfa M, DeGagne P, Olson N, Puchalski T. Comparison of ion plasma, vaporized hydrogen peroxide, and 100% ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer. Infect Control Hosp Epidemiol. 1996; 17(2):92-100.

Ayliffe G. O Uso do óxido de etileno e formaldeído/vapor a baixa temperatura em hospitais. Infect Control Hosp Epidemiol. 1989; 17:109-32.

Aylife G, Lowbury E, Gueddes A, Williams JD. Controle de infecção hospitalar. 3ª ed. Rio de Janeiro: Revinter; 1998.

Goveia V, Pinheiro S, Graziano K. Métodos de esterilização por baixa-temperatura e novas tecnologias. Rev Latino-Am Enferm. 2007; 15(3):373-6.

Adler S, Scherrer M, Daschner F. Costs of lowtemperature plasma sterilization compared with other sterilization methods. J Hosp Infect. 1998; 40(2): 125-34.

Álvarez JF, Lorenzo S, Cardín J. Nuevos sistemas de gestión de costes en el ámbito sanitário. Adm Sanit. 1999; 3(11):135-45.

Antunes A, Trevizan M. Gerenciamento da qualidade: utilização no serviço de enfermagem. Rev Latino-Am Enferm. 2002; 8(1):35-44.

Salmon VRR. Validação da esterilização a vapor com baixa temperatura e formaldeído de acordo com a norma en 14180 [dissertação]. Curitiba: Universidade Tecnológica Federal do Paraná; 2008.

Boscariol MR, Moreira AJ, Mansano RD, Kikuchi IS, Pinto TJA. Sterilization by pure oxygen plasma and by oxygen-hydrogen peroxide plasma: an efficacy study. Int J Pharm. 2008; 353(1-2):170-5.

Ayliffe G, Bloomfield S, Russell A, Hugo W. Principles and practice of disinfection, preservation and sterilization. 2nd ed. Oxford: Scientific Publications; 1992.

Baez H, Assaf-Anid N. Novel and conventional approaches to sterilization. Chem Engineering. 2008; 15(8):42.

Bertani NG, Oliveira TA, Alvernaz SS. Análise qualitativa entre os métodos químicos e físicos de esterilização. Rev Educ Meio Ambiente Saúde. 2007; 3(1):223-37.

Batista MA. Eventos adversos e motivos de descarte relacionados ao reuso de produtos médicos hospitalares em angioplastia coronária. Rev Bras Cir Cardiovasc. 2006; 21(3):328-33.

Chu NS, Chan-Myers H, Ghazanfari N, Antonoplos P. Levels of naturally occurring microorganisms on surgical instruments after clinical use and after washing. Am J Infect Control. 1999; 27(4):315-9.

Clasen TF, Thao H, Boisson S, Shipin O. Microbiological effectiveness and cost of boiling to disinfect drinking water in rural Vietnam. Environ Sci Technol. 2008; 42(12):4255-60.

Crow S. Antisepsis, desinfection and sterilization. In: Soule BM, Larson EL, Preston GA. Infections and nursing practice: preventions and control. St. Louis: Mosby; 1995. p.129-50.

Haje DP, Thomazini, JA, Volpon, JB. Efeitos do processamento químico, da esterilização em óxido de etileno e da usinagem em parafusos de osso bovino: estudo com microscopia eletrônica de varredura. Rev Bras Ortop. 2007; 42(4):120-4.

Block SS, Lawrence CA. Disinfection, sterilization, and preservation. Philadelphia: Lea & Febiger; 1991.

Nadador Patino V, Rubio Horcajada M, Ruiz Castro M. Controversy over one use only medical devices. Rev Enferm. 2007; 30(2):56-60.

Published

2011-04-30

How to Cite

Vasconcelos, E. L., & Guillen Solvas, J. F. (2011). Low temperature sterilization and its applicabiliües. Revista De Ciências Médicas, 20(1/2), 31–36. https://doi.org/10.24220/2318-0897v20n1/2a822

Issue

Section

Revisão